GL-CONNECTION SOFTWARE - INTEGRATED WITH THE GL SERIES

Software for high performance and easy operation
allows connections of Graphtec's midiLOGGER series

 

 

The GL7000 can be controlled by the GL-Connection software which is an integrated application software for the GL series.  GL900, GL840, GL820, GL240 and GL220 can also be connected and controlled using the GL connection.

 



VARIOUS MEASUREMENT SCREENS


Measurement signal can be displayed in various types of screens according to various applications.


MULTI-WINDOW FUNCTION, MEASURED SIGNAL CAN BE DISPLAYED IN VARIOUS FORMS


The GL-Connection software supports up to 2000 channels and up to 10 units of the GL series.

It splits up to 4 windows and each window can display different format for monitoring signals from multiple channels.

While the unit of GL series is connected to the PC via Ethernet or USB, GL-Connection software can manage various information such as data capturing, and in free running - displaying data without saving - and data in saved file. The software can also display the saved data on the PC.


TAB FUNCTION


The tab function allows you to manage the screen so that it can be intuitive and easy to control window views. Screen displayed in multi-window can split using the tab.  Items to be displayed can be set in detail, such as GL body level, individual input module level, specified channel, and other settings.

 

COPY OF THE ENTIRE TAB

CHANNEL COPYING

MOVING TABS


INTEGRATED APPLICATION SOFTWARE FOR THE GL SERIES

 

GL-Connection software is an integrated application software for the GL7000 and other GL series.  When the software is used with the GL7000, you can control and display the data along with analysis view.  Data captured by other GL series is compatible with the GL-Connection and APS software.


CONNECTING MULTIPLE UNITS AND INTEGRATING SAVED DATA
 

Available in firmware version 1.60 or later

GL-connection software is be able to manage multiple units in a mixed setup of modules.  Data integration function allows you to understand the overall situation immediately by creating a single file in the same time axis from multiple data saved in separated unit.

 

1. CONNECT MULTIPLE UNITS

2. LINK CONNECTION

(SIMULTANEOUS RECORDING)

3. LINK CONNECTION

(SYNCHRONOUS RECORDING)

4. MIXED CONNECTION

(COMBINATION OF OF NO.1 - 3)

 

Connection method

Model

Model mix

Control of Start/Stop

Data integration

1.Multiple unit connection
GL7000
GL900
GL840
GL820
GL240
GL220

Yes

Control start/stop for each unit

Manually integrate the data after recording

2.Link connection (simultaneous)
GL7000
GL900
GL840
GL820
GL240
GL220

Yes

All units make the start/ stop action with a single control.
* The timing of the action will be synchronized.

All integrated into one file.

3.Link connection (synchronous)

* Sync cable is used to connect each unit.

GL7000

No

All units make the action with full synchronization in a single operation.

It makes automatically after completing the data capture. It can also make manually.

4.Mixed connection, mixing No.1 to No.3 scenarios.

GL7000
GL900
GL840
GL820
GL240
GL220

Way of operation or action vary by type of connection.* Full synchronization can be made when the sync cable is used in the GL7000.


WORK FLOW OF DATA INTEGRATION

  (*1) The integrated file cannot be created when it exceeds 100 units or 100 channels (analog channel + logic channel).  (*2) Data will be integrated with using fastest sampling speed when the sampling speed in each file is different.  (*3) The data format in integrated data file is the GL7000 format even if GL series is included to capture the data.

 

(*1) The integrated file cannot be created when it exceeds 100 units or 100 channels (analog channel + logic channel). 

(*2) Data will be integrated with using fastest sampling speed when the sampling speed in each file is different. 

(*3) The data format in integrated data file is the GL7000 format even if GL series is included to capture the data.


MAIN FUNCTION OF SOFTWARE

Item

GL-Connection
(version 1.80 or later)
GL100_GL240_GL840-APS GL220_820-APS GL900-APS

Connec-tion

Supported model

GL7000
GL900-4/-8 (Firmware ver. 3.01 or later)
GL840 (Firmware ver. 1.21 or later)
GL820 (Firmware ver. 1.08 or later)
GL240 (Firmware ver. 1.21 or later)
GL220 (Firmware ver. 1.06 or later)
GL840
GL820
GL240
GL220
GL100
GL220
GL820
GL200A
GL800
GL900-4 / GL900-8

Max. number of unit

10 10 10 1

Max. number of channel

Up to 2000 channels

Up to 1000 channels

Up to 500 channels

4 or 8

Mixing the USB & LAN

Possible

Possible

N/A

N/A

Display

Splitting of screen

Up to 4 screens

No, single screen

No, single screen

No, single screen

Group function

Up to 20 groups

Up to 4 groups

Up to 4 groups

N/A

SUPPORTED MODEL AND CONDITION OF CONNECTION

Supported model

Connected by USB

Connected by LAN

Wireless LAN

Notice

GL7000

Yes

Yes

N/A

(1) GL series up to 10 units

(2) Up to 2000 channels

GL840 Yes Yes Yes *4
GL820

Yes

Yes

N/A
GL240 Yes N/A Yes *4
GL220

Yes

N/A N/A
GL900

Yes

Yes

N/A

(*4) using B-568 option.

<  back to top


FUNCTIONS

Item

Description

Statistics / Display

Display statistical calculation result.

Capturing data: Maximum, Minimum, Peak or Average

Replaying data: Maximum, Minimum, Peak, Average or RMS in between cursors

File operation

Converts binary data to the CSV data (specific period, all data in one file, multiple files), Creates a new file with compression or by consolidating multiple files.

Search function

Search any point on the data.

Level: Specific level in any channels

Alarm: Occurred alarm in any channel

Time: Beginning, center, end of the data, Trigger point, Specific time (absolute, relative), Specific number

Warning function

Send e-mail to the specified address when the alarms occur

 
Member Login
Welcome, (First Name)!

Forgot? Show
Log In
Enter Member Area
My Profile Not a member? Sign up. Log Out