GL100-WL, GL100-N MAIN UNIT

 

 

DUAL PORT ADAPTOR CONNECTS UP TO 2-MODULES FOR SIMULTANEOUS INTERFACE

Connect 1 sensor of the same type.  Number of channels and measurement type are fixed with each input module.

GL100-WL / N

Illuminance/UV sensor, Temp/Humidity sensor

GL100-WL / N

Carbon dioxide sensor, Temp/Humidity sensor

GL100-WL / N

Carbon dioxide sensor, Illuminance/UV sensor


MULTI-FUNCTION INPUT TERMINALS / A VARIETY OF SENSOR TO CORRESPOND TO THE APPLICATION

 

SENSORS

 

 

INPUT TERMINALS / ADAPTER

 
 

Recording Condition  >>   Learn More


GL100-WL, GL100-N MAIN UNIT SPECIFICATIONS

Item Description
Number of channels Varies by the input module used, and measurement type is fixed with each input module
Input method, Type of input terminal
Output signal Alarm (1 channel), solid state switch with optical isolation (Optocoupler, Max. load is the 30 V, 50 mA)
Interface to PC USB (micro USB B type connector), Wireless LAN (WLAN) in GL100-WL
Wireless LAN (in GL100-WL) Standards: IEEE802.11b, Communication distance: approx. 40 m
* It varies by the condition of the LAN. Real-time transfer rate is up to 500ms. The WLAN is able to disable. (It is enabled in the factory default setting)
Storage device Built-in memory: RAM (Approx. 4.9 MB)
External memory: microSD memory card
* Maximum file size for captured data is 1.9MB. It is recommended to use the microSD memory card that supports sleep mode. (Example: TS4GUSDHC4, made by Transcend)
Display LCD (backlit monochrome, graphical type 128 x 64 dots)
Contents: Captured data and Setting menu (Stored data is not able to replay. It is able to replay using the PC application software.)
Functions • Real-time data capturing
• Display the captured data value to the LCD in real-time and save the monitoring values
• Set conditions using the Menu setting
While using USB port:
• Output captured data in real-time
• Output the saved data from the internal memory
• Full control of the GL100 from the PC application software
While using Wireless LAN (in GL100-WL):
• Output captured data in real-time
• Output the saved data from the internal memory
• Full control of the GL100 from the PC application software
• Simple control of the GL100 from the application software of Smart Device
• Send warnings via the e-mail
Alarm • Action
Outputs the signal when the measuring data reaches the present conditions of alarm
• Source
Level of measuring data
• Detecting method
Condition: Higher or lower (signal is higher or lower than the threshold)
Combination: OR
Trigger • Action
Start or stop the recording of captured data by trigger
• Source
Start trigger: OFF, Level (*), Alarm, or Date
Stop trigger: OFF, Level (*), Alarm
* Level trigger is available in the analog input of the GS-4VT, GS-4TSR, and GS-3AT module.
• Detecting method of the Level (*)
Condition: Rising or Falling (signal is passed through the threshold)
Combination: OR or AND
Dustproof and waterproof IP54 compatible (*)
* It is effective only in the condition that the input module is set to the GL100 and then the covers of connector and battery are closed. It is recommended to replace the packing of cover in periodically.
Power source • Alkaline battery (AA size x 2)
• USB bus-power (5V, 200 mA) (*)
* When AC adapter for USB device is used, the required power capacity is 5V, 1A. Battery and AC adapter is not included.
Operating environment Temperature: -10 °C to 50 °C
Humidity: up to 80 % RH (non condensed)
External dimension [W x D x H] Approx. 66 x 100 x 27 mm (exclude protrusion)
Weight GL100-N: Approx. 125 g, GL100-WL: Approx. 130
 

INPUT MODULE AND ACCESSORIES

No. Input module Measurement (actual sensing) Measurement (calculated value)
1 Temp./Humidity sensor
GS-TH
Temperature (-20 to 85 ºC),
Humidity (0 to 100 % RH)
Accumulated temperature,
Dew-point temperature
2 Acceleration/Temp. sensor
GS-3AT
Acceleration in 3-axis (max. 10 G),
Temperature (-10 to 50 ºC)
N/A
3 Illuminance/UV sensor
GS-LXUV
Illuminance (max. 200 k lx),
UV intensity (max. 30 mW/cm2)
Accumulated Illuminance,
Accumulated UV intensity
4 Carbon dioxide sensor
GS-CO2
CO2 concentration
(max. 9999 ppm)
N/A
5 Voltage/Temp. input module
GS-4VT
Voltage (max. 50 V) or Temp. (TC: K/T type) of 4 ch,
Logic or Pulse of 4 ch
6 Temperature input terminal
GS-4TSR
Thermistor (max. 120 ºC) of 4 ch,
Logic or Pulse of 4 ch
7 Thermistor sensor
GS-103AT-4P
Temperature sensor (-40 to 105 ºC), Normal type
use with GS-4TSR module
8 Thermistor sensor
GS-103JT-4P
Temperature sensor (-40 to 120 ºC), Ultrathin type
use with GS-4TSR module
9 AC current sensor adapter
GS-DPA-AC
AC current,
2 sensors are able to connect (*1)
Power (instantaneous),
Integrated power (Electric energy)
10 AC current sensor
GS-AC50A
Clamp-on type (max. 50 A AC),
use with GS-DPA-AC module
11 AC current sensor
GS-AC100A
Clamp-on type (max. 100 A AC),
use with GS-DPA-AC module
12 AC current sensor
GS-AC200A
Clamp-on type (max. 200 A AC),
use with GS-DPA-AC module

 

 

NO. 1 TEMPERATURE / HUMIDITY SENSOR, GS-TH

The compact GL100 temperature humidity datalogger sensor is designed for industries requiring climate monitoring and control such as greenhouse, hydroponics, agriculture and botanical rooms giving maintenance techs real time environment and climate monitoring solution. Fine arts museums and galleries are also served well for controlled environment settings where the GL100 excels! Remote real-time temperature humidity data monitoring is capable with the GL100 wireless model.

GS-TH
Relative Temperature and Humidity Sensor
 
Measurement Data
Temperature, Humidity, Dew Point Temperature (calculated value)
Accumulated Temperature ºCh
Accumulated Temperature only recorded
Measurement Range
±2G (20m/s2, ±5 (50m/s2, ±10 (100m/s2
(Gravitational Acceleration 1G=approx. 9.807m/s
 
Measuring Method
C-MOS sensor
Range of Temperature Measurement
-20ºC to 85ºC
Temperature Measurement Degree of Accuracy
-20 ≤TS < 0 ±0.8(ºC)
0 ≤TS < 60 ±0.5(ºC)
60 < TS ≤85 ±0.8ºC
Range of Humidity Measurement
0.0 - 100.0% RH
Humidity Measurement Accuracy
At 25ºC
±1.0% RH (0-10% RH)
±8% RH (10-20% RH)
±5% RH (20-80% RH)
±8% RH (80-90% RH)
±10% RH (90-100% RH)

Response Time (Temperature)
Temperature, Humidity: approx. 100 seconds to reach 63% at 25ºC with airflow speed of 1m/s(1)
Processor Functionality
Accumulated Temperature: 0 to 999,999kº ch(2)
Memory Capacity (Memory Mode)
16 | 32 | 64 | 128k sample
Pre-trigger
(Memory Mode)
OFF/10 | 25 | 50 | 100% of selected memory
Sampling Interval
0.5 | 1 | 2 | 5 | 10 | 20 | 30 sec
1 | 2 | 5 | 10 | 20 | 30 | 60 min
Alarm
OFF/level
Temperature Unit of Denomination
ºC/ºF (selectable)
Waterproofing
Waterproof protection filter at the connection point.
 
Operating Environment
Within range of Temp/Humidity measurement.(3)
External Dimensions
15mm x 45mm x 10.2mm (excludes protrusion)
Weight
Approx. 14g (0.49 oz)

(1) Varies by operating environment.
(2) Reset count at start of recording; exceeding or falling below standard temperature.
(3) With GL100 main unit.


 

 

NO. 2 ACCELERATION AND TEMPERATURE SENSOR, GS-3AT

Item Description
Type of measurement Tri-axial aceleration (X-, Y-, Z-axis) and Temperature
Measuring range Acceleration ±2 G (20m/s2), ±5 G (50m/s2), ±10 G (10m/s2)
Temperature -10 to 50 °C (using C-MOS sensor)
Accuracy Acceleration ±2 % of F.S. (including non linearity)
Temperature -10 ≤ TS < 50: ± 1.0 °C
Response (acceleration measurement) 0 Hz to 100 Hz
Measuring mode Memory, or Direct mode
Memory capacity 16, 32, 64, 128 k Samples (for memory mode)
Pre-trigger 10, 25, 50, 100 % of selected memory capacity, and OFF (function is available for memory mode)
Sampling interval Memory mode: 5, 10, 20, 50, 100 ms
Direct mode: 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes
Calculation function (in Direct mode) Function: The data is captured in every 5ms interval, and then the result of calculation between selected interval will be saved.
Type of calculation: Average, Peak, RMS, or OFF (selected one value will be saved)
Unit of temperature measurement Switchable °C and °F
Offset adjustment function OFF, ON (sets the static acceleration value of current to zero)
Dustproof and waterproof IP54
Length of cable Approx. 200 mm
Operating environment Temperature: -10 °C to 50 °C
Humidity: up to 80 % RH (non condensed)
External dimension [W x D x H] Approx. 51 x 36 x 20 mm (exclude protrusion)
Weight Approx. 64 g


 
GL100-Sensor-No.3.jpg

 

NO. 3 ILLUMINANCE AND UV SENSOR GL-LXUV

The compact GL100 datalogger illuminance and UV sensor for industries requiring accurate light metering with UV ray strength and accumulated luminance monitoring. This is the perfect hardware application for greenhouse, hydroponics, agriculture and botanical rooms giving maintenance techs real time environment and climate monitoring. Fine arts museums and galleries are also served for controlled environment settings.

Item
Description
GS-LXUV
Luminance (0 lux to 200k lux) and
UV rays (0 to 30mW/cm2)
Dual sensor module
 
Measurement Data
Luminance, UV ray strength, Accumulated Luminance(1)
Accumulated UV ray strength(1)
 
Measurement ch
Luminance
1ch
UV Ray
1ch
Measurement Range
Luminance
0 lux to 200k lux
UV Ray
0 to 30mW/cm2
Measurement Degree of Accuracy
Luminance
±5%
UV Ray
±5%
Spectrum of Accuracy
Luminance
400 to 750nm (peak 560nm)
UV Ray
260 to 400nm (peack 370nm)
Measurement Resolution
Luminance
0.1 lux
UV Ray
0.001mW/cm2
Response Time
Luminance
1ms or less
UV Ray
1ms or less
Processor Functionality
Luminance
0 to 999,999 klxh
UV Ray
0 to 999,999W/cm2  (2)
Sampling Intervals
0.5 | 1 | 2 | 5 | 10 | 20 | 30 sec
1 | 2 | 5 | 10 | 20 | 30 | 60 min
Extension Cable
Approx 200mm
Operating Environment
-10º to 50ºC, 80% RH and below (non-condensed)
External Dimensions
46mm x 66mm x 19mm (excludes protrusion)
Weight
65g (2.29 oz)

(1) Displays accuumulated value only during recording
(2) Accumulated value resets when recording starts or QUIT key is pressed


 

 

NO. 4 CARBON DIOXIDE SENSOR, GS-CO2

The compact GL100 datalogger CO2 density sensor designed for industries requiring climate monitoring and control solution such as greenhouse, hydroponics, agriculture and botanical areas where operators need real time environment and climate monitoring. Fine arts museums and galleries are also served for controlled environment settings where the GL100 excels!

Item
Description
GS-CO2
CO2 density sensor with a measuring range of 0-9,999ppm concentration.
 
Sensor Method
NDIR System (non disperv infrared)
Measurement Data
CO2 Concentration
 
Measurement Channels
1ch
Measurement Range
0 to 9,999ppm
Measurement Accuracy
±(5% of rdg + 30ppm) In the range between 0 and 5000ppm
Response Time
3 minutes or less
Sampling Intervals
0.5 | 1 | 2 | 5 | 10 | 20 | 30 sec
1 | 2 | 5 | 10 | 20 | 30 | 60 min
CO2 sampling interval is 2 seconds or slower. For sampling selection slower than 2 seconds, same values are recorded and new values are updated every 2 seconds.
Calibration
ON / OFF
Extension Cable
Approximately 20cm
Operating Environment
0º to 50ºC, 80% RH and below (non-condensed)
External Dimensions
66mm x 100mm x 24.6mm (excludes protrusion)
Weight
99g (3.49 oz)

 

 

NO. 5 4CH VOLTAGE / TEMPERATURE TERMINAL, GS-4VT

Connects the GL100 for up to 4ch of voltage DC (20mV to 50V as well as 1-5V) and thermocouple (K or T type) temperature measurement. Each voltage / temperature channel is configurable. Combination of pulse and logic channels can be measured at the same time.

Item Description
Type of measurement Analog voltage or Temperature,
Logic (signal pattern) or Pulse (instant or accumulated count)
Number of channel Voltage/Temperature: 4 channels (measurement type for channels can each be separately selected)
Logic/pulse: 4 channels (measurement type for channels can be selected as set of 4 channels)
Input method of voltage/temp. Scans by the photo-MOS-relay, all channels isolated input
Measuring range of voltage 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50 V F.S. and 1-5V F.S.
Measuring accuracy 0.15 % of F.S.
Input impedance 1 M ohms
Maximum input voltage Between positive ("+") and negative ("-") input terminal: 60 V
Between negative ("-") terminal of channels: 60 V
Between negative ("-") terminal of channel and "GND": 60 V
Withstand voltage Between negative ("-") terminal of channels: 350 V p-p (1 minute)
Between negative ("-") terminal of channel and "GND": 350 V p-p (1 minute)
Measuring range of temperature Thermocouple: K type -200 °C to 1370 °C, T type -200 °C to 400 °C
Measuring accuracy K type -200 ≤ TS ≤ -100 °C: ± (0.05% of reading + 2.0 °C)
-100 < TS ≤ 1370 °C: ± (0.05% of reading + 1.0 °C)
T type -200 ≤ TS ≤ -100 °C: ± (0.1% of reading + 1.5 °C)
-100 < TS ≤ 400 °C: ± (0.1% of reading + 0.5 °C)
Reference Junction Compensation (R.J.C.): ± 0.5 °C
Burnout checking Displaying warning when Thermocouple has failed
Unit of temperature measurement Switchable °C and °F
Input of Logic/Pulse Input signal: Voltage or Dry contact signal
Voltage input: 0 to +24V (common ground)
Dry contact signal: Relay or Solid state relay
Threshold voltage: Approx. +2.5V, Hysteresis: Approx. 0.5V (Status of the signal is changed in the 2V and the 2.5V.)
Measuring rage of Pulse Instant count: up to 200 counts/sampling interval
Accumulated count: up to 65535 counts (Accumulated value is reset by starting the data recording or pressing the QUIT key.)
Sampling interval 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes
Length of cable Approx. 200 mm
Operating environment Temperature: -10 °C to 50 °C
Humidity: up to 80 % RH (non condensed)
External dimension [W x D x H] Approx. 46 x 66 x 36 mm (exclude protrusion)
Weight Approx. 85 g

 

 

NO. 6 TEMPERATURE INPUT TERMINAL / 4 CH THERMISTOR, GS-4TSR

Item Description
Type of measurement Temperature,
Logic (signal pattern) or Pulse (instant or accumulated count)
Number of channel Temperature: 4 channels (measurement type for channels can each be separately selected)
Logic/pulse: 4 channels (measurement type for channels can be selected as set of 4 channels)
Input method of temperature Scans by the photo-MOS-relay, all channels non-isolated input
Temperature sensor Thermistor (optional)
Measuring range Temperature: -40 to 120 °C (varies by the type of sensor)
(Sensor GS-103AT-4P: -40 to 105 °C, GS-103JT-4P: -40 to 120 °C)
Measuring accuracy • GL100 main body
-40 ≤ TS < 0 °C: ± 0.7 °C
0 ≤ TS ≤ 35 °C: ± 0.2 °C
35 < TS ≤ 70 °C: ± 0.4 °C
70 < TS ≤ 120 °C: ± 1.0 °C
• Thermistor sensor (GS-103AT-4P or GS-103JT-4P)
Typical ± 0.4 °C
Unit of temperature measurement Switchable °C and °F
Input of Logic/Pulse Input signal: Voltage or Dry contact signal
Voltage input: 0 to +24V (common ground)
Dry contact signal: Relay or Solid state relay
Threshold voltage: Approx. +2.5V, Hysteresis: Approx. 0.5V (Status of the signal is changed in the 2V and the 2.5V.)
Measuring rage of Pulse Instant count: up to 200 counts/sampling interval
Accumulated count: up to 65535 counts (Accumulated value is reset by starting the data recording or pressing the QUIT key.)
Sampling interval 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes
Length of cable Approx. 200 mm
Operating environment Temperature: -10 °C to 50 °C
Humidity: up to 80 % RH (non condensed)
External dimension [W x D x H] Approx. 46 x 66 x 36 mm (exclude protrusion)
Weight Approx. 83 g

(1) Measurement type for each channel can be seperately selected.
(2) A contact point, b contact point, NO, NC.
(3) Clear accumulated value by pressing the QUIT key or when you start recording.


 

 

NO. 7-8 THERMISTOR SENSOR, GS-103JT-4P, GS-103JT-4P

Item Description
Connectable input module All types of input module, Cable is connected between the input module and the GL100.
Length of cable Approx. 1.5 m
Operating environment Temperature: -10 °C to 50 °C, Humidity: up to 80 % RH (non condensed)

 

 

NO. 9 AC CURRENT SENSOR ADAPTER, GS-DAP-AC

Item Description
Number of sensors Two (2) sensors
Connectable sensors GS-TH (Temp./Humidity), GS-CO2 (Carbon dioxide (CO2)), GS-LXUV (Illuminance & Ultraviolet)
It is not able to connect two sensors of the same type.
Length of cable Approx. 200 mm
Operating environment Temperature: -10 °C to 50 °C
Humidity: up to 80 % RH (non condensed)
External dimension [W x D x H] Approx. 46 x 66 x 27 mm (exclude protrusion)
Weight Approx. 68 g

NO. 10-12 AC CURRENT SENSOR, GS-AC50A, GS-AC100A, GS-AC200A

Item Description
GS-AC50A Rated measuring current: 50 A AC (Length of cable to adapter is approx. 200 mm)
GS-AC100A Rated measuring current: 100 A AC (Length of cable to adapter is approx. 200 mm)
GS-AC200A Rated measuring current: 200 A AC (Length of cable to adapter is approx. 200 mm)

RECORDING CONDITIONS

 

Recording destination: internal memory (calculated by 4.9 MB)

Sampling: 30 sec. or 1 min

Max recording tie = (max capacity + record length) x sampling interval


Dual Port Sensor Models for the GL100

Combo models for GL100-WL:

Temp./Humidity Set: GL100-WL-TH GL100-WL & GS-TH

Acceleration Set: GL100-WL-3AT GL100-WL & GS-3AT

Voltage/Temp. Set: GL100-WL-4VT GL100-WL & GS-4VT

Thermistor Set: GL100-WL-4TSR GL100-WL & GS-4TSR


* Thermistor sensor is not included. 

Combo models for GL100-N:

Temp./Humidity Set: GL100-N-TH GL100-N & GS-TH

Acceleration Set: GL100-N-TH GL100-N & GS-3AT

Voltage/Temp. Set: GL100-N-4VT GL100-N & GS-4VT

Thermistor Set: GL100-N-3TSR GL100-N & GS-3TSR


* Thermistor sensor is not included.

 
 