FEATURES

 

GL840 OFFERED IN TWO MODELS:

MULTI-INPUT MODEL & WITHSTAND-VOLTAGE MODEL

GRAPHTEC MIDI DATA LOGGER GL840-M MULTI-INPUT MODEL, AND GL840-WV HIGH VOLTAGE WITHSTAND MODEL
 

3-INPUT SYSTEMS ENABLE TO MEASURE VARIOUS SIGNALS

Type 1: Multifunction universal analog input ports

Contains a highly isolated input channel system which ensures that signals are not corrupted by noise from other channels.  GL840's inputs are suitable for combined measurements from voltage, temperature, humidity, logic, and pulse signals.  Standard configuration has 20 analog input channels.  Unit is expandable of up to 200 channels by adding optional 20 channel extension terminal base units (B-566) and input terminal blocks (B-564 or B-565).

GRAPHTEC MIDI DATA LOGGER GL840-WV WITHSTAND MODEL 20-CHANNELS COME STANDARD EXPANDABLE UP TO 200 CHANNELS
Withstand voltage & Accuracy Multi-input type (GL840-M/B-564) Withstand-voltage type (GL840-WV/B-565)
Voltage Input voltage range 20 mV to 100 V 20 mV to 100 V
Max. voltage (Input - GND) 60 Vp-p 300 Vp-p
Temp. Thermocouple R, S, B, K, E, T, J, N, W (WRe5-26)
RTD (Resistance Temp. Detector) Pt100 (IEC751), Pt1000 (IEC751), JPt100 (JIS)
Accuracy Voltage ± 0.1% of F.S. ± (0.05% of FS + 10μV)
Temperature* ± 1.55 ºC ± 1.1 ºC

* Accuracy rating for K-type thermocouple at 100˚C includes reference junction compensation. Accuracy varies by temperature levels and thermocouple types.

 

How a standard configuration is expanded to more than 40 channels (below)

GRAPHTEC MIDI DATA LOGGER GL840 HOW A STANDARD CONFIGURATION IS EXPANDED TO MORE THAN 40 CHANNELS
 

Q: How do you configure the expansion blocks on the GL840 series?

There are several components that are required to set up the expansion terminal blocks for the GL840 models. Each model will require one expansion cable to connect the first expansion terminal base which would initially connect the first 20 channel block with the main instrument. The original 20 channel block from the main unit will snap out of the body, and the corresponding 20 channel block will then snap on to the first extension terminal base. This cable can now be either 1.6 ft (50cm) or 6.5 ft (2 meter) long. Thereafter, depending upon how many channels you will need to configure, each corresponding extension terminal base (B-566) will add additional 20 channel blocks either via a cable or directly daisy-chaining on to each other. Either the B-564 20 channel terminal block for the GL840-M or the B-565 20 channel terminal block for the withstand model GL840-WV can be used as the terminal block mixed together on the series of channel blocks.

 

Q: What are the key advantages for using the GL840-WV, and which applications do you recommend for the GL840-WV?

The key advantage of the GL840-WV model is in the precision accuracy of its measurement and its capability to withstand higher voltage requirements. Voltage accuracy on DC input is ±0.05% of full scale (+10µV), and average accuracy for thermocouple measurement increases by anywhere from 0.5˚C to 1.7˚C depending upon the range and the type of your typical thermocouple wires. (please review the specification below to review your specified range) The other key advantage is in its ability to withstand up to 300Vp-p channel-to-ground and 600Vp-p in between channels with 2300Vrms AC (for 1 minute) channel-to-ground. This provides the monitoring ability to connect series stacked cells for power batteries up to 300V with no issues as a viable monitoring tool for battery efficiency and performance. Solar panel networks and other power grid networks can now be monitored with this cost-efficient monitoring tool.



 

Configuration for additional channels

Number of channels

20 channels

40 channels

100 channels

200 channels

GL840 unit (GL840-M or GL840-WV)

1 set

1 set

1 set

1 set

Connection cable (B-567-05 or -20)

N/A

1 pc

1 pc

1 pc

Terminal base (B-566)

N/A

2 sets

5 sets

10 sets

Input terminal (B-564 or B-565 )

N/A

1 set

4 sets

9 sets
 

Offers longer cable for the input terminals

Input terminal blocks can be connected directly (in daisy chain), or using the B-567 cable(s). This allows the input terminals to be placed in separate locations according to the need of the application.  The input terminal unit and the GL840 main body can be extended by using an extended connections cable.

* If the signal is affected by noise, it may be required to use a slower sampling.

GRAPHTEC MIDI DATA LOGGER GL840 OFFERS LONGER CABLE FOR THE INPUT TERMINALS

Type 2: GS digital sensors

The GL840 multi-channel data logger allows users to switch sensors and terminals for measuring various signals.  Digital sensors and input terminal/adapters for the GL100 connects to the GL840 directly.  Available sensors/terminals to measure various signals with the GL840 data loggers are:

GL840 (configuration example) shown with dual port adapter (GS-DPA), CO2 sensor & illuminance/UV sensor

GL840 (configuration example) shown with dual port adapter (GS-DPA), CO2 sensor & illuminance/UV sensor


Type 3: Four-Channels of Logic/Pulse inputs

 

Supports 4-channels logic or pulse signal inputs. Pulse mode allows cumulative, instant, or rotational values for industrial measurement capability with speed and flow.

GRAPHTEC MIDI DATA LOGGER GL840 FOUR-CHANNELS OF LOGIC / PULSE INPUTS

MAXIMUM SAMPLING INTERVAL OF UP TO 10 MS

Provides faster sampling rates for voltage measurements.  Up to 10 ms sampling speed is achievable when limiting the number of channels in use.

Sampling Interval

10ms 20ms 50ms 100ms 200ms 500ms 1s 2s

Number of channel

1 2 5 10 20 50 100 200

Measuring

Voltage

Temperature

- - -

BUILT-IN 4 GB FLASH MEMORY WITH SD CARD SUPPORT

The new GL series enables reliable long term measurment with its built-in 4 GB flash memory and SD card slot for external storage devices.  The SD card slot supports an SDHC memory card of up to 32 GB.  The captured data can be stored in GBD (Graphtec binary data) or CSV file format.

Capturing time* (when all 20 analog channels are being used with Logic/Pulse inputs turned off.)

Sampling

10ms 50ms 100ms 200ms 500ms 1s 10s

GBD format

31 days 77 days 95 days 108 days 270 days Over 365 Over 365

CSV format

3 days 11 days 16 days 21 days 54 days 109 days Over 365

Figures are approximate. File size of captured data is 2GB in GBD or CSV file format on this chart.  Sampling interval is limited by the number of channels in use. (10ms:1ch, 50ms:5ch, 100ms:10ch). Limited sampling speed is available when digital sensors and GL100-WL are used as a remote monitoring device.

 

RING CAPTURE FUNCTION

GRAPHTEC MIDI DATA LOGGER GL840 RING CAPTURE FUNCTION

The most recent data is saved when the memory is configured in ring memory mode. (Number of capturing data is 1000 to 2000000 points)

RELAY CAPTURE FUNCTION

GRAPHTEC MIDI DATA LOGGER GL840 RELAY CAPTURE FUNCTION

Data is continuously saved to multiple files up to 2GB without losing any data until capturing is stopped when the memory is configured in the relay mode.

HOT-SWAPPING THE SD MEMORY CARD

GRAPHTEC MIDI DATA LOGGER GL840 HOT SWAPPING THE SD MEMORY CARD

SD card can be replaced during data capturing when the sampling interval is 100ms or slower.


USEFUL FUNCTIONS

Displays the data by a bar chart (in firmware ver.1.10 or later)

GRAPHTEC MIDI DATA LOGGER GL840 USEFUL FUNCTIONS CONNECTS GS SENSOR TO GL840, CONNECT GL100-WL TO GL840 USING W-LAN

 

The integrated data that is measured by the digital sensors can be displayed by a bar chart in the GL840 series.

GRAPHTEC MIDI DATA LOGGER GL840 USEFUL FUNCTIONS BAR CHART MODE, STACKED BAR CHART MODE
Available GS sensors Measurement Unit
GS-TH (Temp/Humidity) sensor Integrated temperature ℃h
GS-DPA-AC adapter with GS-Acxxx sensor (AC current/power) Integrated power kWh
GS-LXUV (Illuminance/UV) sensor Integrated illuminance lxh or klxh
Integrated UV mW/cm2h
 

ALARM OUTPUT FUNCTION

GRAPHTEC MIDI DATA LOGGER GL840 ALRM OUTPUT FUNTION

Alarm signals can be placed using the four channel alarm output ports based on set conditions for each channel.
* Optional cable (B-513) is required.

USB DRIVE MODE

GRAPHTEC MIDI DATA LOGGER GL840 USB DRIVE MODE

USB drive mode function enables data to be transferred to the PC from GL840 by drag & drop feature.

NAVIGATION FUNCTION

GRAPHTEC MIDI DATA LOGGER GL840 NAVIGATION FUNCTION

Simple to use navigation screen allows setting operation for measurement and wireless LAN adapter.

 

LARGE 7-INCH WIDE COLOR LCD

GRAPHTEC MIDI DATA LOGGER GL840 LARGE 7 INCH WIDE COLOR LCD

Monitoring data can be displayed in waveform or digital form. Parameter settings can be displayed on the screen.

3-TYPES OF POWER SOURCE

GRAPHTEC MIDI DATA LOGGER GL840 3-TYPES OF POWER SOURCE

Choose from AC power supply, DC supply* or the rechargeable battery pack.*
* Optional accessories (B-514 or B-569) are required.

NETWORKING FEATURES

GRAPHTEC MIDI DATA LOGGER GL840 NETWORKING FEATURES

Various functions are available using a network.
Web & FTP server function, FTP client function, NTP client function

 

MATH FUNCTIONS FOR SCALING

GRAPHTEC MIDI DATA LOGGER GL840 MATH FUNCTIONS FOR SCALING

Math Functions are available for scaled input from sensors and transducers with VDC scaled output or 4-20mA current loop.

 
 

FTP Client Function: Captured data is periodically transferred to the FTP server for backup.
NTP Client Function: The clock on the GL840 is periodically synchronized with the NTP server.
(The GL840 requires connection to a LAN environment using the Ehternet/WLAN ports for networking functions)


GL840-M EXTERNAL DIMENSIONS

Scale: mmTolerance: +/- 3 mm

Scale: mmTolerance: +/- 3 mm

 

GL840-WV EXTERNAL DIMENSIONS

Scale: mmTolerance: +/- 3 mm

Scale: mmTolerance: +/- 3 mm


INPUT TERMINAL / BASE UNIT

 

■ Input terminal (B-564) with Base unit (B-566)

GRAPHTEC MIDI DATA LOGGER GL840 INPUT TERMINAL / BASE UNIT

■ Input terminal (B-565) with Base unit (B-566)

GRAPHTEC MIDI DATA LOGGER GL840 INPUT TERMINAL B-565 WITH BASE B-566

■ Base unit for input terminal (B-566)

GRAPHTEC MIDI DATA LOGGER GL840 BASE UNIT FOR INPUT TERMINAL B-566

■ When two Base unit are connected.

Scale: mmTolerance: +/- 3 mm

Scale: mmTolerance: +/- 3 mm


DIN RAIL B-570 DIMENSIONS

 
GRAPHTEC MIDI DATA LOGGER GL840-WV DIN RAIL B-570 DIMENSIONS
GRAPHTEC MIDI DATA LOGGER GL840-M DIN RAIL B-570 DIMENSIONS