WR300 / WR310 SERIES

ARRAY-CORDERS MEMORY RECORDER

 
 

The WR310 Series Thermal Arraycorders are economical waveform recorders available in 4, 8 and 16 channel configurations. Unlike old-fashioned paper-only recorders, the WR310 series is a 21st century technology through and through.

Available are convenient 2-channel plug-in modules that adapt the WR300 to a wide variety of input types and sensors, including voltages up to 500 V, strain gages, thermocouples, frequency/RPM signals, and more. There’s also a logic input amp which offers the same number of inputs as the base machine (4, 8, or 16).

Capture data to memory, to the paper, or to the optional hard drive* or PCM-CIA flash RAM memory card. Data are shown all the time of the 8.4″ color LCD screen in a variety of formats, including scroll. oscilloscope, XY, and even FFT! Data can be printed in real time or after acquisition, to the built-in 100 or 200 mm wide chart output.*

Ethernet and USB interfaces are built-in so that you can control the system from your computer (OPS software is included). The same software and interfaces can also transfer data to your computer and convert it to several popular formats, including Excel and delimited ASCII.

WR300 16-channel unit left side – showing 8 WR3 series 2-channel input amps plugged in, plus 4 x 4-ch logic amps (round connectors below)

 

VARIOUS CHART TYPES AND SIZES ARE SUPPORTED

WR300 8 or 16-ch unit with the optional Z-fold paper take-up capability

EASY OPERATION - INTUITIVE CONTROLS

A separate bank of chart speed setting keys enables you to change the chart speed at any time, and four directional cursor keys are provided for easy menu selection. The additional buttons of the WR310 makes this unit even easier to use than similar products. 

WIDE FORMAT PRINTING*

The wide 200 mm (8 inch) paper allows data to be printed with ultimate clarity and precision – even better than what can be shown on the built-in LCD display. 

DATA UPLOAD TO YOUR PC

OPS023 control/transfer/conversion software is included, so you can convert data captured to Excel™ or delimited ASCII format. Need more analysis power? FlexPro™ can open Graphtec data files natively, providing a powerhouse analytical capabilities with an Excel-like interface

Excel is a registered trademark of Microsoft Corporation
FlexPro is a trademark of Weisang GMBH

 

MAIN FEATURES

  • Models available with 4, 8 or 16 input channels
  • 8.4″ color LCD monitor for data display and the graphical user interface
  • Plug-in 2-channel WR3 series amplifiers adapt the system to a wide variety of input types and sensors.
  • Up to 1 MS/s sampling rate on all channels
  • Bandwidth (frequency response): dc to 50 kHz
  • 1 MSample internal memory PER CHANNEL is standard
  • Built-in 200mm (8″) wide thermal array printer in the 8- and 16-ch models; 100 mm wide printer in the 4-ch model
  • Interfaces: Ethernet, USB, and slot for flash memory cards
  • Performance, reliability and ease of use Includes PC software for control, data transfer and conversion to popular formats

 

  OPTIONS & UPGRADES

  • WR3 series plug-in modules (2-ch each)
  • 40 GB internal HDD*
  • Flash memory cards for the PCM-CIA drive
  • 4-, 8-, or 16-channel logic input module
  • IRIG time code interface option*
  • DC power option in lieu of 120/240 VAC 50/60 Hz 

 

* WR310 series 8 and 16 channel models are available with the IRIG and 40 GB hard drive (HDD) options. WR300 series models are not compatible with these options. the WR300-4 four channel model has a 100mm wide chart instead of 200mm wide chart. 

 

WR3320A

LINEARCORDER

The WR3320A Linearcorder Mark VII is a thermal writing pen oscillograph which has been designed to meet the standards required by even the most exacting of professionals, including government agencies all over the world.  This is a proud testament to their reliability and legendary performance.

 

WR7700

ARRAY-CORDER

 

DOWNLOAD

 

WR7700 Software  (668 KB)    >>    Download Now

Control and Data Transfer Program – connects via RS232 only. Does not allow any on-line visualization of waveforms. A handy setup utility which allows unlimited setups, easy text entry, and data transfer/conversion to ASCII.


WR8000

ARRAY-CORDER

 

DOWNLOAD

 

WR8000 Software V1.02 (689 KB)     >>    Download Now

Control and Data Transfer Program – connects via RS232 only. Does not allow any on-line visualization of waveforms. A handy setup utility which allows unlimited setups, easy text entry, and data transfer/conversion to ASCII.


WR9000

ARRAY-CORDER

 

WR1000

ARRAY-CORDER

 

GL1100 / GL1000

DATA PLATFORMS

 

GL820

 

BROCHURE & DOWNLOAD

 

GL820 Brochure Data Sheet in pdf  (1.4 MB)     >>    Download Now

GL820 User Manual V1.51 in pdf  (11.7 MB)    >>    Download Now

GL820 Application Software User Manual V1.51 APS in pdf  (7.6 MB)      >>    Download Now

GL820 GL Connection User Manual V1.51 APS in pdf  (3.4 MB)     >>    Download Now

 

GL820 Software V1.80  (15.6 MB)    >>    Download Now

The GL-Connection application software is software used to perform USB and LAN connections with the GL, to configure GL settings, and to carry out data recording, data playback and real-time display of input signals.
Compatibility: Windows Vista – 10

GL820 Software V1.80 Release Note in pdf  (94 KB)    >>    Download Now

GL820 Software V1.12  (69 MB)    >>    Download Now

The GL-Connection application software is software used to perform USB and LAN connections with the GL, to configure GL settings, and to carry out data recording, data playback and real-time display of input signals.
Compatibility: Windows Vista – 8.1

GL820 USB Driver V2.03(1.9 MB)    >>    Download Now

GL820 Firmware Update V1.13  (2.7 MB)    >>    Download Now


GL800

 

BROCHURE & DOWNLOAD

 

GL800 User Manual V1.52 in pdf  (6.3 MB)      >>     Download Now

GL800 Quick Start Guide in pdf  (2 MB)      >>     Download Now

GL800 Spec Sheet in pdf  (839 KB)      >>     Download Now

 

GL800 Software APR V1.04  (72 MB)      >>     Download Now

Control and Data Transfer Program – connects via either Ethernet or USB 2.0. Allows on-line visualization of recorded data. Allows transfer of data from the instrument to your computer, and the conversion of data files from Graphtec binary files to ASCII text or Excel formats.
Windows 2000 – 7

GL800 USB Driver V2.03(1.9 MB)      >>     Download Now

USB Driver for Windows Vista – 8


GL500 / GL500A

 

BROCHURE & DOWNLOAD

 

GL500 User Manual in pdf  (3.7 MB)     >>     Download Now

GL500A User Manual in pdf  (8.6 MB)     >>     Download Now

GL500A Application Manual in pdf  (2.2 MB)     >>     Download Now

 

GL500 Software  (23 MB)     >>     Download Now

Control and Data Transfer Program – connects via either Ethernet or USB 2.0. Allows on-line visualization of recorded data. Allows transfer of data from the instrument to your computer, and the conversion of data files from Graphtec binary files to ASCII text or Excel formats.
Windows 2000, XP, Vista


GL400 / GL450

 

GL220

 

BROCHURE & DOWNLOAD

 

GL220 Brochure and Data Sheet in pdf  (1.3 MB)     >>     Download Now

GL220 User Manual in pdf  (7.6 MB)     >>     Download Now

GL220 GL Connection User Manual in pdf  (3.4 MB)     >>     Download Now

GL220 Application Software User Manual in pdf  (7.6 MB)     >>     Download Now

 

GL220 Software V1.80 (15.4 MB)     >>     Download Now

The GL-Connection application software is software used to perform USB and LAN connections with the GL, to configure GL settings, and to carry out data recording, data playback and real-time display of input signals.
Compatibility: Windows Vista – 10

GL220 Release Note V1.80 in pdf (94 KB)     >>     Download Now

GL220 Software APS V1.12 (69 MB)     >>     Download Now

The GL-Connection application software is software used to perform USB and LAN connections with the GL, to configure GL settings, and to carry out data recording, data playback and real-time display of input signals.
Compatibility: Windows Vista – 8.1

GL220 USB Driver V2.03 >>     Download Now


GL200

 

BROCHURE & DOWNLOAD

 

GL200 Data Sheet in pdf (706 KB)     >>     Download Now

GL200 Input Unit Specifications in pdf (51 KB)     >>     Download Now

 

GL200 Software APS V1.40  (68.4 MB)     >>     Download Now

Control and Data Transfer Program – connects via either Ethernet or USB 2.0. Allows on-line visualization of recorded data. Allows transfer of data from the instrument to your computer, and the conversion of data files from Graphtec binary files to ASCII text or Excel formats.
Windows 2000 – Vista

GL200 USB Driver V2.03  (1.9 MB)     >>     Download Now


GL200A

 

BROCHURE & DOWNLOAD

 

GL200A User Manual in pdf (4.5 MB)      >>     Download Now

GL200A Quickstart Guide in pdf (2.5 MB)      >>     Download Now

 

GL200A Software APS V1.40  (71.6 MB)     >>     Download Now

Control and Data Transfer Program – connects via either Ethernet or USB 2.0. Allows on-line visualization of recorded data. Allows transfer of data from the instrument to your computer, and the conversion of data files from Graphtec binary files to ASCII text or Excel formats.
Windows 2000 – 7

    GL200 USB Driver V2.03  (1.9 MB)     >>     Download Now

     
     